ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Filter Element|Description and Operation|Page 2507 > < Air Filter Element|Description and Operation
Page 1
background image

Air Filter Element: Testing and Inspection

Air Restriction Gauge

Air Restriction Gauge

The 7.3L diesel engine air induction system uses an air restriction indicator to indicate when to change the air cleaner element. The air cleaner
element should be replaced when the yellow band in the indicator reaches the CHANGE FILTER mark. Engine performance and fuel economy are
adversely affected when maximum restriction is reached. After servicing the air cleaner element, the air restriction indicator can be reset by
pushing the button on the end of the indicator. The air restriction indicator is located on the clean-air side of the engine air cleaner.

Air Inlet Restriction Check

The best method for determining dry-type air cleaner maintenance periods on diesel equipped vehicles is by periodically checking the air
restriction indicator. It is recommended that the air restriction indicator be used to determine service intervals. A visual inspection of the air
cleaner element will not determine the need for service. Overservicing is not recommended.

Air Cleaner Element 

CAUTION: If the air cleaner element, engine air cleaner or air cleaner outlet tube is removed, use a clean shop rag to prevent contaminants from
entering the engine.

1. Replace the air cleaner element according to the maintenance schedule.
2. Check the old air cleaner element. It could help to detect foreign material on the sealing surface that is causing leakage. A streak of dust on the

clean air side of the air cleaner element seal is the tell-tale sign. If it exists, be sure the cause is removed before installing a new air cleaner
element.

3. Inspect the new air cleaner element for damage. Always look for possible shipping or handling damage. Pay particular attention to the seals. Check

for cuts, etc.. Do not use a damaged air cleaner element.

4. Insert the new air cleaner element properly. Cover pressure is not necessary to compress the air cleaner element seal.

Air Filter Element|Description and Operation|Page 2507 > < Air Filter Element|Description and Operation