ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Electrical Specifications|Page 5199 > < Remote Battery Jumper Terminal|Diagrams
Page 1
background image

Alternator: Electrical Specifications

Item.....................................................................................................................................................................................................................Specification

Single Generator

Gas (3G)........................................................................................70/115 amps (max) @ 1,800-6,000 generator rpm, approximately 525-2,000 engine rpm
Gas (6GLF)...................................................................................82/135 amps (max) @ 1,800-6,000 generator rpm, approximately 525-2,000 engine rpm
Voltage.........................................................................................................................................................................................................................12 volts

Generator

Load at 2,000 rpm (Standard)..................................................................................................................................................................................70 amps
Load at 2,000 rpm (Extra Heavy-Duty Option).......................................................................................................................................................82 amps
No Load at 2,000 rpm...............................................................................................................................................................between 13.2 and 15.5 volts