ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Customer Safety Information|Page 7079 > < Customer Safety Information|Page 7077
Page 3
background image

2. Place the connector position assurance lever in the full release position before attempting to connect the connector.

 

3. CAUTION: Putting the large RCM electrical connector into the RCM on an angle can cause bad electrical connections and damaged components.

With the large RCM electrical connector uniformly aligned, lightly push in until a subtle audible click is heard and slight resistance is felt.

 

4. CAUTION: Do not push the connector onto where the lever pivots and seats itself. Light pressure is needed to get the connector into position on

the RCM before using the lever to fully seat the connector.

Push the large electrical connector position assurance lever until the retainer engages and locks into place.

 

Customer Safety Information|Page 7079 > < Customer Safety Information|Page 7077