Econoline E150 1/2 Ton V6-4.2L VIN 2 (1998)
Compressor Fitting HVAC: Service and Repair
REMOVAL
1. Using proper procedures, recover the refrigerant.
2. Disconnect the battery ground cable.
3. Remove the engine air cleaner (ACL) and the air cleaner outlet tube.
4. Disconnect the A/C pressure cut-off switch electrical connector.
5. Move the compressor discharge line isolator.
1. Remove the screw.
2. Move the compressor discharge line isolator.