6. Install the compressor discharge line isolator.

1. Install the compressor discharge line isolator.
2. Install the screw.

7. Connect the condenser to evaporator tube.

1. Connect the condenser to evaporator tube.

NOTE:  Lubricate the new O-rings with Motorcraft YN-12c refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B.

2. Install the O-rings.
3. Install the screw.

CAUTION:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

8. Connect the auxiliary evaporator to compressor tube spring lock coupling.