Econoline E150 1/2 Ton V8-5.4L CNG VIN M (1998)
1. Position the exhaust inlet pipe, new exhaust gasket and exhaust hanger bracket.
2. Install the exhaust hanger insulator brackets and nuts.
3. Install the exhaust hanger insulators.
NOTE: A soap and water solution will ease the installation of the exhaust insulators.
4. Install the LH and RH nuts.
5. Connect the heated oxygen sensor electrical connectors.