Econoline E150 1/2 Ton V8-5.4L SOHC VIN L (1999)
Refrigerant Pressure Sensor / Switch: Description and Operation
A/C Pressure Cutoff Switch
A/C Pressure Cut-Off Switch
The A/C pressure cut-off switch is used to interrupt A/C compressor operation in the event of high system discharge pressures.
^
The A/C pressure cut-off switch is mounted on a Schrader valve-type fitting on the high pressure side of the A/C pressure cut-off switch.
^
A valve depressor, located inside the threaded end of the A/C pressure cut-off switch, presses on the Schrader valve stem.
^
This allows the A/C pressure cut-off switch to monitor the compressor discharge pressure.
^
When the compressor discharge pressure rises to approximately 2,896 kPa (420 psi), the switch contacts open, disengaging the A/C compressor.
^
When the pressure drops to approximately 1,724 kPa (250 psi), the contacts close to allow operation of the A/C compressor.
^
It is not necessary to discharge the refrigerant system to remove the A/C pressure cut-off switch.