Torque Converter: Service and Repair
4R100

Torque Converter Cleaning and Inspection

1. If the torque converter is being replaced, continue with sub-step 2 of Step 2.
2. If the torque converter is not being replaced the following procedures must be performed:

1

The torque converter must be thoroughly cleaned.
-

Torque converter with drain plugs may be cleaned by using the special tool.

-

Torque converter without drain plugs may be cleaned by hand. Partially fill the torque converter using only the recommended transmission
fluid for the applicable transmission. Hand-agitate the torque converter and then thoroughly drain the fluid. Refill the torque converter with
new fluid specified for the transmission, and install.

2

NOTE:  5.4L engine applications will still use the in-tank coolers. The oil-to-air (OTA) cooler will be used as an auxiliary cooler for this
application only.

The oil-to-air (OTA) cooler must be replaced when contamination is present in the transmission. Do not try to clean or backflush the OTA
cooler or the contamination may be reintroduced into the transmission, causing transmission assembly damage.
The in-tank and auxiliary coolers must be thoroughly cleaned by forward and backward flushing.

3

The cooler lines must be thoroughly cleaned by backward and forward flushing.

4

All cooler bypass valves (CBV), if equipped, must be thoroughly cleaned.

5

Perform the Transmission Fluid Cooler Flow Test.

6

If the transmission cooling system fails the Transmission Fluid Cooler Flow Test, the fluid cooler (OTA), cooler bypass valve, and or cooler
lines must be replaced.

7

If the cooler-by-pass valve (CBV) needs to be replaced, refer to Cooler Bypass Valve. Use only factory-approved service parts.

Torque Converter Flushing

1. CAUTION:  Mineral spirits used to clean the torque converter must be fresh, non-chlorinated and non-halogenated.

Following the instructions included with the Torque Converter/Transmission Oil Cooler Cleaner, flush the torque converter.

2. After flushing, drain the remainder of the solvent through the converter drain plug.
3. Add 1.9 liter (2 qt.) of clean MERCON(R) V Automatic Transmission Fluid XT-5-QM or equivalent Meeting MERCON(R) V specification

approved fluid into the converter fluid filler tube and agitate by hand.

4. Thoroughly drain the solution.

Torque Converter Service and Replacement