Econoline E250 3/4 Ton V6-4.2L VIN 2 (1998)
Expansion Block/Orifice Tube: Service and Repair
Broken Orifice Tube Extractor
Fixed Orifice Tube
SPECIAL TOOL(S)
REMOVAL
1. Remove the condenser to evaporator tube.
-
For a fixed orifice tube, perform Steps 2 and 3.
-
For a broken orifice tube, perform Steps 4 and 5.
2. Engage the Fixed Orifice Tube Remover/Replacer to the A/C evaporator core orifice.
3. Hold the tool T-handle stationary and rotate the tool body to remove the A/C evaporator core orifice.