ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Oil Cooler, Transmission|Page 4164 > < Transmission Cooler, A/T|Flow of Diagnosis|Page 4161
Page 1
background image

Transmission Cooler: Service and Repair
Oil Cooler, Transmission

Backflush/Cleaning

1. Conduct backflushing with a Torque Converter/Oil Cooler Cleaner. Test your equipment to make sure that a vigorous fluid flow is present before

proceeding. Replace the system filter if flow is weak or contaminated.

2. To aid in attaching the cleaner to the transmission steel cooler lines, connect two additional rubber hoses to the transmission end of the steel

transmission cooler lines.
^

Connect the cleaner tank pressure line to the steel transmission cooler return line (top line at the transmission case fitting).

^

Connect a tank return hose to the steel transmission cooler pressure line (bottom line at the transmission case fitting). Place the outlet end of
this hose in the solvent tank reservoir.

3. Turn on solvent pump and allow the solvent to circulate a minimum of 5 minutes (cycling switch on and off will help dislodge contaminants in

cooler system).

4. Switch off the solvent pump and disconnect the solvent pressure hose from the transmission cooler return line.
5. Use compressed air to blow out the cooler(s) and lines (blow air into the transmission cooler retune line) until all solvent is removed.
6. Remove the rubber retune hose from the remaining steel cooler line.

Removal and Installation

Removal 

1. Remove the front radiator air deflector.
2. Remove the radiator grille.
3. Remove the radiator grille opening panel reinforcement.
4. With a suitable drain pan properly positioned, disconnect the fluid cooler tubes at the transmission fluid cooler.
5. Remove the auxiliary transmission fluid cooler.

Installation 

1. Follow the removal procedure in reverse order.
2. Fill the transmission to the proper level and inspect for leaks.

Backflushing and Cleaning

CAUTION:  Test the Torque Converter/Oil Cooler Cleaner to ensure that a vigorous fluid flow is present before proceeding. Replace the system filter
if flow is weak or contaminated.

1. NOTE:  Rubber hoses must be attached to the ends of the fluid cooler tubes, to aid in connecting them to the cleaner.

Connect the cleaner pressure and return lines appropriately.
1

Connect the pressure line to fluid cooler inlet tube.

2

Connect the return line to fluid cooler outlet tube.

3

Place the outlet end of the return line in the solvent tank reservoir.

2. NOTE:  Cycling the solvent pump on and off will help dislodge contaminants in the cooler system.

Oil Cooler, Transmission|Page 4164 > < Transmission Cooler, A/T|Flow of Diagnosis|Page 4161