Econoline E350 1 Ton V8-5.4L SOHC VIN L (1999)
Vacuum Reservoir HVAC: Service and Repair
REMOVAL
1. Remove the evaporator core housing assembly.
2. Remove the vacuum reservoir tank.
1
Remove the screw.
2
Drill out the heat stake.
3
Remove the vacuum reservoir tank.
3. Disconnect the vacuum harness.
INSTALLATION
1. Follow the removal procedure in reverse order.
NOTE: Use a screw in place of the heat stake to install the vacuum reservoir.