ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Intake Manifold|Removal|Page 2720 > < Intake Manifold|Removal|Page 2718
Page 6
background image

18. Connect the following vacuum connections.

1

Fuel pressure regulator vacuum connector (not shown on 4.6L illustration)

2

Engine vacuum regulator vacuum connector

3

EGR vacuum connector

4

Vapor management valve vacuum connector

19. Connect the EGR valve to exhaust manifold tube upper fitting. 

On 4.6L engines, tighten both fittings starting at the top in two stages.

*

Hand tighten.

*

Tighten to 35-45 Nm (26-33 ft. lbs.). 
On 5.4L engines, tighten both fittings starting at the top in three stages.

*

Hand tighten.

*

Tighten the upper fitting to 35-45 Nm (26-33 ft. lbs.).

*

Tighten the lower fitting to 55-65 Nm (41-47 ft. lbs.).

Intake Manifold|Removal|Page 2720 > < Intake Manifold|Removal|Page 2718