Evaporative System Service Port: Service and Repair

REMOVAL 

1. Remove the air cleaner inlet tube.

2. Insert a small screwdriver into the locking mechanism on the evaporative emission test port retainer (the protective cap can be removed for easier

access).

3. Open the attaching clip and remove it from the transmission fluid level tube assembly.
4. Pull the evaporative emission test port tube loose from the clip.