ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Multiple Junction Connector > < Micro ISO Relay|Testing and Inspection
Page 1
background image

Mini ISO Relay: Testing and Inspection

RELAY COMPONENT TEST - MINI ISO RELAY

Using 73 Digital Multimeter, check for the continuity between Terminal 85 and all other terminals. If the resistance is 5 ohms or less between Terminal
85 and any other terminal, install a new relay. If the resistance is greater than 5 ohms, continue with the test. Using two jumper wires, connect relay
Terminals 86 and 30 directly to the positive battery terminal. Using 73 Digital Multimeter set in the volts position, check for voltage at Terminal 87A. If
battery voltage is not indicated, install a new relay. If battery voltage is indicated, connect a third jumper wire to Terminal 85 and ground the jumper
wire to a known good ground. Check for voltage at Terminal 87. If battery voltage is not indicated, install a new relay.

Multiple Junction Connector > < Micro ISO Relay|Testing and Inspection