ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Standard A/C|Page 6023 > < Accumulator HVAC|Service Precautions|Page 6020
Page 1
background image

Accumulator HVAC: Service and Repair
Standard A/C

REMOVAL

1. Recover the refrigerant.

NOTE:  Installation of a new suction accumulator/drier is not required when repairing the air conditioning system except when there is physical
evidence of system contamination from failed A/C compressor or damage to the suction accumulator/drier.

2. Remove the battery.

3. Remove the battery tray.

1

Remove the screws.

2

Remove the battery tray.

4. Disconnect the evaporator discharge line.

CAUTION:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

5. Disconnect the compressor suction line.

1

Remove the screw.

2

Disconnect the compressor suction line.

CAUTION:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

Standard A/C|Page 6023 > < Accumulator HVAC|Service Precautions|Page 6020