ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Expansion Valve|Locations|Page 6261 > < Expansion Valve|Locations|Page 6259
Page 1
background image

Expansion Valve: Service and Repair

Auxiliary Climate Control

REMOVAL

1. Remove the A/C evaporator core.

2. Separate the capillary bulb from the outer evaporator outlet tube.

1

Remove the A/C insulating tape.

2

Remove the clip securing the capillary bulb to the tube.

NOTE:  Care must be taken not to damage the capillary bulb or tube.

3. Remove the A/C evaporator expansion valve.

1

Disconnect the refrigerant lines.
^

Disconnect the A/C liquid jumper line.

^

Disconnect the inlet line.

CAUTION:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

2

Remove the A/C evaporator expansion valve.

INSTALLATION

1. Install the A/C evaporator expansion valve.

1

Install new green O-ring seals.
^

Lubricate with clean PAG Refrigerant Compressor Oil (R-134a Systems) or equivalent.

NOTE:  The green O-ring seals cannot be seen. They are located in the connections.

Expansion Valve|Locations|Page 6261 > < Expansion Valve|Locations|Page 6259