ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Evaporative System Service Port > < Evaporative Emission Control Canister|Service Precautions|Page 3442
Page 2
background image

6. Remove the evaporative emission canister vent solenoid.

NOTE:
^

Inspect and install new O-ring seals as necessary.

^

A twisting and pulling motion is necessary to remove the evaporative emission canister vent solenoid.

7. Remove the evaporative emission canister outlet elbow.

NOTE:
^

Inspect and install new O-ring seals as necessary.

^

A twisting and pulling motion is necessary to remove the inlet fitting.

8. Remove the Evaporative Emission (EVAP) canister.

1

Remove the bolt and mounting bracket.

2

Remove the evaporative emission canister.

INSTALLATION

1. To install, reverse the removal procedure.

^

Carry out the evaporative emission system leak test.  See: Testing and Inspection/Component Tests and General Diagnostics/Evaporative
Emission System Leak Test

^

Carry out the evaporative emission repair verification drive cycle.  See: Testing and Inspection/Component Tests and General
Diagnostics/Evaporative Emission Repair Verification Drive Cycle

NOTE:  Lubricate the O-ring seals with MERPOL(R) O-Ring Seal Lubricant or equivalent meeting Ford specification ESE-M99B144-B.

Evaporative System Service Port > < Evaporative Emission Control Canister|Service Precautions|Page 3442