ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Evaporative System Service Port|Service and Repair|Page 3447 > < Evaporative Emission Control Canister|Service Precautions|Page 3443
Page 1
background image

Evaporative System Service Port: Service and Repair

REMOVAL

1. Remove the air cleaner inlet tube.

2. Insert a small screwdriver into the locking mechanism on the evaporative emission test port retainer (the protective cap can be removed for easier

access).

3. Open the attaching clip and remove it from the transmission fluid level tube assembly.
4. Pull the evaporative emission test port tube loose from the clip.

Evaporative System Service Port|Service and Repair|Page 3447 > < Evaporative Emission Control Canister|Service Precautions|Page 3443