Page 30
background image

-

Is the voltage greater than 10 volts?

Yes

GO to M2.

No

VERIFY the SJB fuse 13 (5A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the Wiring Diagrams to identify the possible causes of the circuit
short. CLEAR the
DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
M2 CHECK THE SDARS MODULE GROUND CIRCUIT FOR AN OPEN

-

Ignition OFF.

-

Disconnect: Negative Battery Cable.

-

Measure the resistance between the SDARS module C4344-3, circuit GD148 (BK/YE), harness side and ground.

-

Is the resistance less than 5 ohms?

Yes

GO to M3.

No

REPAIR the circuit. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
M3 CHECK THE MS-CAN CIRCUITS BETWEEN THE SDARS MODULE AND THE DLC FOR AN OPEN

-

Measure the resistance between the SDARS module C4344-1, circuit VDB06 (GY/OG), harness side and the DLC C251-3, circuit VDB06
(GY/OG), harness side.

-

Measure the resistance between the SDARS module C4344-7, circuit VDB07 (VT/OG), harness side and the DLC C251-11, circuit VDB07
(VT/OG), harness side.

-

Are the resistances less than 5 ohms?

Yes

Initial Inspection and Diagnostic Overview|Page 3043 > < Initial Inspection and Diagnostic Overview|Page 3041