ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3081 > < Initial Inspection and Diagnostic Overview|Page 3079
Page 68
background image

-

Is the concern still present?

Yes

INSTALL a new HVAC module. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
U48 CHECK FOR CORRECT SDARS MODULE OPERATION

-

Disconnect the SDARS module connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the SDARS module connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new SDARS module. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
U49 CHECK FOR CORRECT IC OPERATION

-

Disconnect the IC connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the IC connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new IC. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
U50 CHECK FOR CORRECT LTM OPERATION

-

Disconnect all the LTM connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the LTM connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

Initial Inspection and Diagnostic Overview|Page 3081 > < Initial Inspection and Diagnostic Overview|Page 3079