Edge FWD V6-3.5L (2007)
Position the flush tool kit plug into the thermostat housing to control the flow and thermostat housing cover, and bolts Tighten to 10 Nm (89 lb-in). See
Figure 6.
14. NOTICE:
With the heater core inlet and outlet hoses off from step 11:
^
Connect the heater core inlet hose (1B - lower hose) to the heater return port (upper port) on the thermostat housing.
^
Connect the flush tool kit drain hose to the heater core inlet port on the thermostat housing.
^
Connect the flush tool kit hose-to-pump to the heater core outlet hose (OB) for the reverse flushing.
15. Route the flush tool kit drain and fill hoses under the thermostat housing and out of the engine compartment Make sure that the hoses are NOT
kinked.