Coupler HVAC: Service and Repair
Air Conditioning Line (Peanut) Fitting

AIR CONDITIONING LINE (PEANUT) FITTING

Disconnect

1. Remove the nut and separate the 2 halves of the peanut fitting.

2. CAUTION:  Do not use metal tools to remove the O-ring seal. They can cause axial scratches across the O-ring seal groove, resulting in 

refrigerant leaks.

Remove the O-ring seal with a non-metallic tool.

Connect

1. Clean all dirt or foreign material from the fittings.

2. CAUTION:  Use only new, green, O-ring seals. The use of any O-ring seals other than those specified may result in intermittent leakage

during vehicle operation.

Install the O-ring seal.
-

Lubricate the O-ring seal with mineral oil.

3. Lubricate the inside of the fittings with mineral oil.

Spring Lock Coupling|Page 5473 > < Spring Lock Coupling|Page 5471