Main Relay (Computer/Fuel System) > < Procedures|Page 2864
Page 2
background image

4. Attach the wiring harness retainer to the cowl stud bolt.

5. Restore the module configuration. Carry out the module configuration restore steps of the Programmable Module Installation (PMI) procedure.  

See: Information Bus/Testing and Inspection/Programming and Relearning

6. Reprogram the PATS. Carry out the Parameter Reset procedure.  See: Accessories and Optional Equipment/Antitheft and Alarm Systems/Testing

and Inspection/Programming and Relearning/Passive Anti-Theft System (PATS) Parameter Reset

7. Using the scan tool, perform the Misfire Monitor Neutral Profile Correction procedure, following the on-screen instructions.