Is the voltage greater than 10 volts?

Yes

GO to A4.

No

GO to A3.

-------------------------------------------------
A3 CHECK THE HORN RELAY COIL GROUND CIRCUIT FOR AN OPEN

-

Disconnect: SJB C2280b.

-

Measure the resistance between the SJB C2280b-41, circuit CRH03 (BN), harness side and the clockspring C218-1, circuit CRH03 (BN), harness
side.

-

Is the resistance less than 5 ohms?

Yes

GO to A10.

No

REPAIR circuit CRH03 (BN) for an open. REPOWER the SRS. REFER to Restraint Systems. TEST the system for normal operation.

-------------------------------------------------
A4 CHECK FOR VOLTAGE TO THE CLOCKSPRING USING THE CONNECTOR GROUND

-

Measure the voltage between the clockspring C218-1, circuit CRH03 (BN), harness side and the clockspring C218-7, circuit GD112 (BK/GN),
harness side.

-

Is the voltage greater than 10 volts?

Yes

Initial Inspection and Diagnostic Overview|Page 7961 > < Initial Inspection and Diagnostic Overview|Page 7959