ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 8069 > < Initial Inspection and Diagnostic Overview|Page 8067
Page 3
background image

Yes

For the license plate lamps, REPAIR circuit GD149 (BK) for an open. TEST the system for normal operation.

For all others, GO to P5.

No

REPAIR circuit CLS30 (VT/WH) or circuit CLS30 (RD) for an open. TEST the system for normal operation.

-------------------------------------------------
P5 CHECK FOR VOLTAGE TO THE INOPERATIVE PARKING LAMP USING THE CONNECTOR GROUND

-

Measure the voltage between the inoperative lamp, harness side as follows:

-

Is the voltage greater than 10 volts?

Yes

INSTALL a new bulb holder. TEST the system for normal operation.

No

REPAIR the ground circuit in question for an open. TEST the system for normal operation.

-------------------------------------------------
P6 CHECK FOR CORRECT SJB OPERATION

-

Disconnect all the SJB connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the SJB connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

Initial Inspection and Diagnostic Overview|Page 8069 > < Initial Inspection and Diagnostic Overview|Page 8067