background image

Yes

CONNECT the negative battery cable. GO to V30. 

No

GO to V23.

-------------------------------------------------
V23 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE ACM DISCONNECTED

-

Disconnect: ACM C240b .

-

Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and ground; and between the DLC C251-11, circuit
VDB07 (VT/OG), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT the negative battery cable. GO to V31. 

No

If the vehicle is equipped with an APIM, GO to V24. 

If the vehicle is not equipped with an APIM, GO to V25.

-------------------------------------------------
V24 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE APIM DISCONNECTED

-

Disconnect: APIM C3338 .

-

Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and ground; and between the DLC C251-11, circuit
VDB07 (VT/OG), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT the negative battery cable. GO to V32. 

No

GO to V25.

-------------------------------------------------
V25 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE HVAC MODULE
DISCONNECTED

-

Disconnect: HVAC Module C2356a (DATC) or C2357a (EMTC) .

-

Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and ground; and between the DLC C251-11, circuit
VDB07 (VT/OG), harness side and ground.