20. Connect the driver air bag module electrical connector.

21. Install the driver air bag connector access cover.

22. WARNING:  The restraint system diagnostic tool is for restraint system service only. Remove from vehicle prior to road use. Failure to

remove may result in injury and possible violation of vehicle safety standards.

Remove the special tool to the instrument panel harness side of the passenger air bag module electrical connector.

23. Connect the passenger air bag module electrical connector.
24. Raise the glove compartment.

-

Press the locking tabs.

25. Connect the battery ground cable.
26. Prove out the air bag system.

Front Seat|Page 7882 > < Front Seat|Page 7880