ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

A/C - Musty or Mildew Type Odors|Page 6456 > < A/C - Musty or Mildew Type Odors|Page 6454
Page 1
background image

Evaporator Core: Description and Operation

NOTE:  Installation of a new suction accumulator is not necessary when repairing the air conditioning system except when there is physical evidence of
system contamination from a failed A/C component or damage to the suction accumulator.

The A/C evaporator housing contains the A/C evaporator core. The A/C evaporator core is the plate/fin type with a unique refrigerant flow path.

^

A mixture of refrigerant and oil enters the bottom of the A/C evaporator core through the A/C evaporator core inlet tube and is routed so it flows
through the partitioned first four plate/fin sections.

^

The next four plate/fin sections are partitioned to force the refrigerant to flow toward the other end of the A/C evaporator core.

^

The next five plate/fin sections are partitioned to force the refrigerant to flow toward the bottom of the A/C evaporator core.

^

Refrigerant then continues through to the remaining five plate/fin sections and then moves out of the A/C evaporator core through the A/C
evaporator core outlet tube.

^

This W-pass flow pattern transfers the flow of refrigerant and oil through the A/C evaporator core.

A/C - Musty or Mildew Type Odors|Page 6456 > < A/C - Musty or Mildew Type Odors|Page 6454