ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Electronic Leak Detection|Page 2278 > < Refrigerant|Capacity Specifications|Page 2275
Page 1
background image

Refrigerant: Testing and Inspection
Electronic Leak Detection

Refrigerent Leak Detector

SPECIAL TOOL(S)

CAUTION:  Good ventilation is necessary in the area where electronic A/C leak testing is to be carried out. If the surrounding air is contaminated with 
refrigerant gas, the leak detector will indicate this gas all the time. Odors from other chemicals such as antifreeze, diesel fuel, disc brake cleaner, or other
cleaning solvents can cause the same problem. A fan, even in a well-ventilated area, is very helpful in removing small traces of contamination from the
air that might affect the leak detector.

1. Leak test the refrigerant system using the Refrigerant Leak Detector. Follow instructions included with leak detector for handling and operation

techniques.

NOTE:  System pressure should be between 413-551 kPa (60-80 psi) at 24°C (75°F) with the engine off.

2. If a leak is found, recover the refrigerant and repair the system.

Electronic Leak Detection|Page 2278 > < Refrigerant|Capacity Specifications|Page 2275