ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refrigerant|Service and Repair > < Electronic Leak Detection|Page 2278
Page 2
background image

2. Turn the valve on the fluorescent tracer dye injector all the way to the left to close the valve.

3. Fill the reservoir with 7 ml (0.25 ounce) of R-134a Fluorescent Tracer Dye 164-R3712.

4. Install the injector between the low-side quick disconnect and the vehicle low-pressure service gauge port valve.
5. Open all quick disconnect valves and charge the refrigerant system.
6. When system charging is complete, recover the refrigerant from the dye injector.
7. Remove the dye injector from the low-side quick disconnect valve.

NOTE:  Only connect the dye-injector to the Manifold Gauge Set or the charging/recovery station when dye is to be injected. The dye injector has
a one-way check valve that will prevent system refrigerant recovery and evacuation.

Refrigerant|Service and Repair > < Electronic Leak Detection|Page 2278