4. Release the clamp and disconnect the auxiliary coolant pump-to-thermostat hose.
5. Release the clamp and disconnect the heater outlet hose.
6. Disconnect the auxiliary coolant flow pump electrical connector.
7. Remove the 2 auxiliary coolant flow pump bolts.
-
To install, tighten to 4 Nm (35 lb-in).
8. Remove the auxiliary coolant flow pump and rubber bracket assembly.
9. NOTE: Lubricate the coolant hoses with plain water only if needed. Do not use soap or other detergents.
To install, reverse the removal procedure.
-
Fill the engine cooling system.