ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Housing Assembly HVAC > < Compressor to Condenser Discharge Line|Page 5515
Page 2
background image

4. Remove the A/C compressor suction fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (11 lb-ft).

5. Detach the wire harness clip from the evaporator outlet line.
6. Remove the thermostatic expansion valve (TXV) fitting nut and disconnect the fitting.

-

Discard the gasket seals.

-

To install, tighten to 15 Nm (11 lb-ft).

7. Disconnect the low-charge protection switch electrical connector.
8. Detach the evaporator outlet line from the receiver/drier bracket.
9. Remove the evaporator outlet line.

10. To install, reverse the removal procedure.

-

Install new gasket seals and a new O-ring seal.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

11. Evacuate, leak test and charge the refrigerant system.