Evacuate, leak test, and charge the refrigerant system.

Evaporator Inlet Line

EVAPORATOR INLET LINE

Removal and Installation

1. Recover the refrigerant.
2. Loosen the nuts and disconnect the evaporator inlet line fittings.

-

Remove and discard the O-rings.

-

To install, tighten to 10 Nm (89 lb-in).

3. Remove the evaporator inlet line.

4. NOTE:  New O-ring seals, lubricated in clean mineral oil, must be installed before reconnecting any A/C fitting which has been disconnected.

To install, reverse the removal procedure.
-

Charge and leak test the refrigerant system.

Evaporator Inlet Line - Orifice Tube

EVAPORATOR INLET LINE - ORIFICE TUBE