Escape AWD V6-3.0L VIN 1 (2004)
4. Verify the repair by operating the system for a short time and inspecting with the UV spot lamp.
Tracer Dye Injection
NOTE: System pressure should be between 413-551 kPa (60-80 psi) at 24°C (75°F) with the engine off.
1. Install the Manifold Gauge Set or a recovery station.
2. Turn the valve on the fluorescent tracer dye injector all the way to the left to close the valve.
3. Fill the reservoir with 7 ml (0.25 ounce) of R-134a Fluorescent Tracer Dye 164-R3712.
4. Install the injector between the low-side quick disconnect and the vehicle low-pressure service gauge port valve.
5. Open all quick disconnect valves and charge the refrigerant system.
6. When system charging is complete, recover the refrigerant from the dye injector.