Accumulator HVAC: Service and Repair
Removal and Installation

SUCTION ACCUMULATOR/DRIER

Removal
1. Discharge the A/C system system into an approved recovery device. 
2. Remove the A/C tube lock coupling clips from the liquid line.
3. Disconnect the condenser to evaporator tube at the evaporator. 
4. Remove the wire harness adjacent to the suction accumulator/drier from the locator bracket. Position the wire harness out of the way.
5. Disconnect the A/C compressor suction manifold and tube from the suction accumulator/drier. Use an appropriate spring lock coupling tool.

6. Disconnect the electrical connector from the A/C cyclic switch.

7. Loosen the mounting strap bolt.

NOTE:  The spring lock coupling tool should be placed around the accumulator tube with the spring in the up position.

8. Disconnect the suction accumulator/drier from the evaporator outlet tube. Use an appropriate spring lock coupling tool.