REMOVAL

1. Discharge and recover the refrigerant from the system. Refer to:  Heating and Air Conditioning, Service and Repair, Discharging and

Recovery, See: Service and Repair/Discharging and Recovery

2. Disconnect the A/C pressure transducer electrical connector.

3. Disconnect the front and rear condenser to evaporator tube spring lock coupling.

CAUTION:  Plug all ports to prevent contamination from dirt or moisture.

4. Disconnect the front condenser to evaporator tube spring lock coupling.

CAUTION:  Plug all ports to prevent contamination from dirt or moisture.

INSTALLATION

1. To install, reverse the removal procedure.
2. Leak test the A/C system.