Page 5
background image

6.

Position the clear plastic water shield over the monitor so the bottom flap wraps around the monitor. See Figure 3.

7.

Using the supplied tie strap, secure the shield to the monitor. Pull the tie strap as tight as possible by hand, then cut off the end of the strap as
illustrated. See Figure 4.

8.

Install the monitor. Be sure the tie strap does not interfere with proper seating of the monitor. Tighten the attaching nuts to 9 Nm (80 lb-in).