Escort L4-122 2.0L SOHC (1997)
Voltage Regulator: Service and Repair
REMOVAL
1. Remove the generator.
2. Remove the generator brush and terminal holder and voltage regulator assembly.
1. Remove the four voltage regulator screws.
2. Remove the assembly.
INSTALLATION
1. Depress the (A) brushes and insert (B) wire to hold brushes during installation.
2. Install the Voltage Regulator (VR) assembly.
1. Position the assembly.
2. Install the four voltage regulator screws and remove the wire.
3. Install the generator.