ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Blower Motor Resistor > < Diagram Information and Instructions|Page 7026
Page 2
background image

Fig. 8 Blower motor removal

LESS AIR CONDITIONING 

1.

Disconnect battery ground cable.

2.

Remove screws securing right ventilator control cable to instrument panel.

3.

Remove screw securing right register duct to lower right edge of instrument panel.

4.

Remove glove box and hinge bar from instrument panel.

5.

Pull right register duct from installed position between air inlet duct and right register opening, Figs. 13 and 15.

6.

Remove ventilator grille from bottom of ventilator assembly, then screws securing right ventilator assembly to blower housing.

7.

Remove hub clamp spring from blower wheel hub, Fig. 15.

8.

Pull blower wheel from blower shaft, then remove three blower motor flange attaching screws.

9.

Pull blower motor from housing, disconnect electrical connector, then remove motor from vehicle.

10.

Reverse procedure to install.

WITH AIR CONDITIONING 

1.

Disconnect battery ground cable.

2.

Remove glove box door and instrument panel lower reinforcement from instrument panel.

3.

Disconnect blower motor electrical connector, then remove blower motor and mounting plate from evaporator housing.

4.

Rotate motor until mounting plate flats clear edge of glove box opening, then remove motor.

5.

Remove hub clamp wheel spring from blower wheel hub and remove blower wheel from motor shaft.

6.

Reverse procedure to install.

Blower Motor Resistor > < Diagram Information and Instructions|Page 7026