ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Inertia Fuel Shutoff Switch > < Air Flow Meter/Sensor|Specifications|Page 4780
Page 1
background image

Air Flow Meter/Sensor: Service and Repair

Fig. 14 Air cleaner hose removal

4-97.6 Engine

1.

Disconnect air outlet hose from air meter and position aside, Fig. 14.

2.

Remove air intake and outlet hoses from air cleaner.

3.

Disengage four spring clamps, then remove air cleaner front cover and filter panel.

4.

Remove four air cleaner-to-air meter attaching screws.

5.

Separate air cleaner base from air meter. Remove gasket and discard if worn or damaged.

6.

Disconnect electrical connector from air meter.

7.

Remove two air meter attaching screws and the air meter.

8.

Reverse procedure to install. Torque attaching screws to 6---9 ft. lbs.

Inertia Fuel Shutoff Switch > < Air Flow Meter/Sensor|Specifications|Page 4780