Escort ZX2 L4-2.0L DOHC VIN 3 (2000)
Coupler HVAC: Service and Repair
Spring Lock Coupling Connect and Disconnect Procedure
Spring Lock Coupling Disconnect Tool Set
SPECIAL SERVICE TOOL(S)
DISCONNECT
1. Perform the Refrigerant Discharging and Recovery Procedure.
2. Remove the A/C tube lock coupling clip.
3. Using the special tool,disengage the spring lock coupling fittings.
4. Remove the O-ring seals with a non-metallic tool.
CAUTION: Do not use metal tools to remove the O-ring seals. They can cause axial scratches across the O-ring seal grooves resulting in
refrigerant leaks.