High Pressure Safety Valve HVAC: Service and Repair

REMOVAL

1. Recover the refrigerant.
2. Raise and support the vehicle. For additional information, refer to Maintenance/Service and Repair.

3. Remove the screws and the radiator air deflector.

4. Remove the A/C compressor pressure relief valve.

INSTALLATION

1. To install, reverse the removal procedure.

-

Lubricate the O-ring seals with PAG Compressor Oil YN-12-C or equivalent meeting Ford specification WSH-M1C231-B.