Vacuum Reservoir HVAC: Service and Repair

REMOVAL

1. Disconnect the battery ground cable.
2. Recover the refrigerant.

3. Disconnect the A/C vacuum line.

CAUTION:  Plug all ports to prevent contamination from dirt and moisture.

4. Disconnect the rear condenser to evaporator line spring lock coupling.

CAUTION:  Plug all ports to prevent contamination from dirt or moisture.

5. Remove the suction line support clip retaining nuts.