Hose/Line HVAC: Description and Operation

NOTE:  Installation of a new suction accumulator/drier is not required when repairing the air conditioning system except when there is physical
evidence of system contamination from a failed A/C compressor or damage to the suction accumulator/drier.

The front condenser to evaporator tube contains high pressure liquid refrigerant. It has the following features:
-

a fitting used to mount the A/C pressure cut-off switch. A long-travel Schrader-type valve stem core is installed in the fitting so that the A/C
pressure cut-off switch can be removed without discharging the A/C system.

-

a fitting used to mount a repairable high-pressure A/C charge port valve.

The rear condenser to evaporator tube contains the A/C evaporator core orifice. When the A/C system is in operation:
-

there is high pressure liquid refrigerant upstream of the A/C evaporator core orifice.

-

there is low pressure liquid refrigerant downstream of the A/C evaporator core orifice.

The A/C manifold and tube is attached to the A/C compressor with O-ring seals and has the following features:
-

the upstream side contains low pressure refrigerant gas and repairable low-pressure A/C charge port valve.

-

the downstream side contains high pressure refrigerant gas and an integral non-repairable muffler.