Escort ZX2 L4-2.0L DOHC VIN 3 (2000)
Daytime Running Lamp Relay: Testing and Inspection
Relay-DRL Control
1. Measure the resistance between relay terminal COM and all other terminals. If any resistance is 5 ohms or less, replace the relay. Otherwise,
continue with the test.
2. Use a jumper wire to apply ground to terminal COIL. Apply battery voltage to terminals NO and COIL. Measure the voltage at terminal COM. If
the voltage is less than 10 volts, replace the relay. Otherwise, return to the pinpoint tests. See: Lighting and Horns/Daytime Running
Lamp/Testing and Inspection/Pinpoint Tests