ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Service and Repair > < A/C Cycling Switch
Page 1
background image

Refrigerant Pressure Sensor / Switch: Description and Operation
Air Conditioning High Pressure Switch

The A/C pressure cut-off switch is used to interrupt A/C compressor operation in the event of high system discharge pressures.

-

The A/C pressure cut-off switch is mounted on a Schrader valve-type fitting on the high pressure side of the condenser to evaporator tube.

-

A valve depressor, located inside the threaded end of the A/C pressure cut-off switch, presses on the Schrader valve stem.

-

This allows the A/C pressure cut-off switch to monitor the compressor discharge pressure.

-

It is not necessary to discharge the refrigerant system to remove the A/C pressure cut-off switch.

-

The A/C pressure cut-off switch has two sets of contacts. One electrical contact is normally closed.

-

When the compressor discharge pressure rises to approximately 2,896 kPa (420 psi), the switch contacts open, disengaging the A/C compressor.

-

When the pressure drops to approximately 1.724 kPa (250 psi), the contacts close to allow operation of the A/C compressor.

The switch contains a second set of electrical contacts used for high-speed fan control.
-

When the compressor discharge pressure reaches approximately 2.241 kPa (325 psi), these contacts close and engage the high-speed fan control.

-

When the pressure drops to approximately 1,896 kPa (275 psi), the contacts again open and the high speed fan control is disengaged.

Refrigerant Pressure Sensor / Switch, HVAC|Service and Repair > < A/C Cycling Switch