ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Valve Cover|LH|Page 2804 > < Valve Cover|LH
Page 2
background image

5.

Disconnect the fuel pressure regulator vacuum hose and lift the fuel charging wiring off the valve cover studs.

6. CAUTION:  Do not use metal scrapers, wire brushes, power abrasive discs or other abrasive means to clean the sealing surfaces. These

tools cause scratches and gouges which make leak paths. Use a plastic scraping tool to remove all traces of old sealant. 

Note: 
^

The intake manifold is shown removed for clarity.

^

The bolts are part of the valve cover and should not be removed.

Remove the LH valve cover.
^

Fully loosen the bolts and remove the valve cover.

^

Inspect the valve cover gasket and clean the mating surface of the cylinder head.

Installation 

1. Note:  If not secured within 4 minutes, the sealant must be removed and the sealing area cleaned with Metal Surface Cleaner F4AZ-19A536-RA or

equivalent meeting Ford specification WSE-M513392-A. Allow to dry until there is no sign of wetness, or 4 minutes, whichever is longer. Failure
to follow this procedure can cause future oil leakage.

Valve Cover|LH|Page 2804 > < Valve Cover|LH