ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Cooling System - Overheating/Coolant Loss|Page 2749 > < Cooling System - Overheating/Coolant Loss|Page 2747
Page 10
background image

With Operations A, B, C,
E, F, G And H)

090803D

2005-2007 Super Duty,

15.5

2004-2005 Excursion 6.0L:

Hrs.

Includes Time To: Test
And/Or Replace EBP
Sensor And Connector If
Required, Perform Turbo
Boost Test, Replace Head
Gaskets (May Be Claimed
With Operations A, B, C,
E, F, G And H)

090803E

2003-2007 Super Duty,

1.5 Hrs.

2003-2005 Excursion 6.0L:
Remove Glow Plugs To
Vent Liquid From
Combustion Chambers,
Should Only Be Claimed If
Engine Is Found To Be
Hydro-locked (May Be
Claimed With Operations
A, B, C, D, F, G And H)

090803E

2004-2009 Econoline 6.0L:

2.4 Hrs.

Remove Glow Plugs To
Vent Liquid From
Combustion Chambers
Should Only Be Claimed If
Engine Is Found To Be
Hydro-locked (May Be
Claimed With Operations
A, B, C, D, F, G And H)

090803F

2003-2007 Super Duty,

2.1 Hrs.

2003-2005 Excursion 6.0L:
Includes Time To: Flush
And Fill Cooling System,
Change Engine Oil And
Filter (May Be Claimed
With Operations A, B, C,
D, E, G And H)

090803F

2004-2009 Econoline 6.0L: 3.0 Hrs.
Includes Time To: Flush
And Fill Cooling System,
Change Engine Oil And
Filter (May be Claimed
With Operations A, B, C,
D, E, G And H)

090803G

2003-2007 Super Duty,

1.0 Hr.

2003-2005 Excursion,
2004-2009 Econoline 6.0L:
Includes Time To:
Re-condition Turbocharger
(May Be Claimed With
Operations A, B, C, D, E,
F And H)

090803H

2003-2007 Super Duty,

0.3 Hr.

2003-2005 Excursion,
2004-2009 Econoline 6.0L:
Includes Time To: Replace
Turbocharger Center

Cooling System - Overheating/Coolant Loss|Page 2749 > < Cooling System - Overheating/Coolant Loss|Page 2747