ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Recall - Overheated Blower Motor Resistors|Page 3944 > < Recall - Overheated Blower Motor Resistors
Page 2
background image

3.

Remove two (2) resistor attaching screws and remove the resistor assembly (Refer to Illustration).

Installation:

1.

Position the new blower motor resistor assembly (Part Number E2FZ-19A706-A) in the opening and install the two (2) attaching screws.

2.

Connect the wire harness connector to the resistor assembly.

3.

Check for proper operation of the blower motor in all blower speeds.

4.

Raise the glove compartment door, while pressing in on each end of the glove compartment liner, until the glove compartment liner tabs re-engage.

Recall - Overheated Blower Motor Resistors|Page 3944 > < Recall - Overheated Blower Motor Resistors