Accumulator HVAC: Description and Operation

NOTE:  Replacement of the suction accumulator/drier is necessary if there is moisture in the system, the system is open for an extended amount of time
or any time a major component is replaced. Major components include:

^

A/C compressor.

^

A/C condenser core.

^

The A/C evaporator core.

^

Refrigerant hose/line.

An A/C evaporator core orifice or an O-ring seal are not considered major components.

The suction accumulator/drier is mounted on the A/C accumulator bracket to the RH side of the instrument panel in the engine compartment. The inlet
tube of the suction accumulator/drier is attached to the A/C evaporator core outlet tube. The outlet tube of the suction accumulator/drier attaches to the 
A/C manifold and tube. A desiccant bag located inside the suction accumulator/drier absorbs any moisture in the refrigerant system.

After entering the inlet of the suction accumulator/drier, heavier oil-laden and liquid refrigerant contacts an internally mounted dome and drips down
onto the bottom of the canister. A small diameter oil bleed hole in the bottom of the vapor return tube allows the accumulated refrigerant and oil mixture
to re-enter the compressor suction line at a controlled rate. A fine-meshed screened filter fits tightly around the bottom of the vapor return tube to filter
out refrigerant system contaminant particles.